Configuration Guide for Plug&Go Model

Modified on Sun, 3 Nov at 3:43 PM

Note: This guide is only for Plug&Charge models. Do not alter the switch settings on Smart Charger models.




Power Downgrade Options for Plug&Go Models

Since Plug&Go models lack connectivity, power downgrade can be achieved in two ways:

  1. Using a DIP switch inside the charger.
  2. Wiring the 3-phase charger to a 1-phase power source.


Accessing and Adjusting Output Power


Locate the DIP Switch
The DIP switch is situated under the LCD/LED panel, just above the input power connection terminals inside the charger.

  • Remove the front cover to access the switch, as shown in the reference image.


DIP Switch Settings
Use the following switch settings to configure the charger:

  • DIP1
    • OFF: Activates the socket version.
    • ON: Activates the cable version.


  • DIP2
    • OFF: Sets the maximum current to 16A.
    • ON: Sets the maximum current to 32A.


  • DIP3
    • OFF: Enables plug-and-charge mode.
    • ON: Enables RFID mode.



 

 DIP "ON" IS UP, DIP "OFF" IS DOWN


ON OFF