The table below only applies to Smart Charger line and lists mostly vendor-specific OCPP keys for changing the charger configuration remotely via OCPP.
For most changes to apply, a reboot (Hard Reset) is required and generally recommended.
Table updated for firmware version 2.1.4 (Morek EV Tool, SD Card update methods).
| OCPP Key | Value | Read Only | Description |
| ChargerMode | 1/2/3 | No | Allows to change the Charge Mode remotely. 1 - APP, 2 - Offline RFID, 3 - Plug&Charge. |
| EnableOfflineDataInPnC | 0/1 | No | By default, the charger only stores offline charging session data in APP Charge Mode. By setting this key to "1", you can modify its behavior to also save and later upload the data in Plug&Charge mode. |
| UnlockConnectorOn EVSideDisconnect | true/false | No | Remotely control if the charger unlocks the cable after it's disconnected from the EV. Only relevant for Socket models. Useful for locking the cable in the socket. |
| WIFIModuleVersion | Wx.x.x | Yes | Indicates the WiFi firmware version in the charger. Useful for troubleshooting WiFi. The latest ATM is W2.3.0. |
| ChargerWifiMac | - | Yes | Indicates the MAC address of the WiFi interface. Useful for troubleshooting WiFi. |
| MaxCurrent | 6-16 (11 kW) 6-32 (7.4/22kW) | No | Global output current (A) limit per phase. |
| DLBMode | 0/1 | No | Allows remotely enabling/disabling DLB mode used with Hub. |
| ExternalLimitPowerEnable | 0/1 | No | Remotely enable/disable Power Distribution (DLM). |
| ExternalLimitPower | Whole number | No | Remotely change the Home Power Current value - DLM current per phase limit (A). |
| ExternalSamplingCurWring | 0/1 | No | Remotely change the Sampling Method for DLM. 0 - CTs, 1 - Power Meter. |
| PowerMeterAddr | Whole number | No | Remotely change address the Power Meter uses for RS485 communication. Must correspond to address set in the Power Meter to work. |
| GridCurrentInterval | Whole number | No | Time interval in seconds for the charger to send live Grid Current parameters obtained either from CTs or Power meter it's connected to. Uses DataTransfer. Set to 0 to disable. |
| SolarMode | 0/1 | No | Remotely enable/disable Solar Mode. 0 - Disabled, 1 - ECO. |
| SolarCurrentFromGrid | Whole number >6 | No | Remotely set the amount of current (A) per phase charger is allowed to pull from grid even when there is no energy Export from PV to Grid. |
| SolarStableTime | Whole number >10 | No | Remotely set the amount of time (s) charger waits before stopping/resuming the charge again when ECO mode is activated. |